Semi-disposable
circle
rebreathing
system
 |
Cyclo-Flo
Circle
rebreathing
system
 |
Mini Lack
Low
Flow Breathing System

 |
|
|
Bodyweight
range 15-40Kg.
The
"SDC" is very often the starting ground for most converts
to low flow aneathesia. Holds 0.4Kg of sodalime, supplied with 2
litre rebreathing bag, parallel patient tubing. Adaptors available
separately to enable use with most anaesthetic machines. A good
starting ground if you are unfamiliar with circle circuits
Stock
code 103-085
With
parallel patient tubing
Stock
code 103-085C
With
co-axial tubing
 |
Bodyweight
range 7-150kg.
The
Cyclo-Flo has incredibly low internal resistance, enabling its use
with small
patients
at low flow rates. Holds 1.3Kg of sodalime. Supplied with 2 litre
rebreathing bag, 1.6mtr parallel patient tubing, V mounting bracket.
Canister is easy to fill, simply release catches on side, Directional
valves are highly visible and can be cleaned without the need for tools.
Ideal
for Isoflurane & Sevoflurane
Stock
code
103-080
 |
Bodyweight
range 1-10kg.
Youll
never want to use a T Piece again!
No bag
twist hazard
Very low resistance
Easy to
clean smooth bore tubing.
Typically
1/3rd the flow rate of a T piece!
Bodyweight range 1~10kg
Saves
gas, Saves Agent.
The safer alternative
 |
|
Co-axial
Bain
non
rebreathing system

|
Magill
non
rebreathing system

|
Modified
Ayres "T"
non
rebreathing
system  |
Parallel
Lack
non
rebreathing system
 |
|
Bodyweight
range 10-25Kg.
Suggested
min. flow rate 2.5 times minute volume. Supplied with Co-axial
tubing set, 2 litre rebreathing bag, bag adaptor and 30mm gas
scavenging valve.
Mapleson
classification:
"D"
Stock
code 103-055
 |
Bodyweight
range 10-40Kg.
Suggested
minimum flowrate 1.5 times minute volume. Supplied with 42"
corrugated tube, 3.5" catheter tube and adaptor, 2 litre
rebreathing bag, bag adaptor and 30mm gas scavenging valve.
Mapleson
classification:
"A"
Stock
code 103-014
 |
Bodyweight
range <10Kgs.
Suggested
minimum flow rate 2.5 times minute volume.Supplied with 1.2mts feed
tubing, feed mount, 1/2 litre rebreathing bag, 30mm gas scavenging
bag adaptor.
Mapleson
classification:
Modified
"F"
Stock
code 103-050
 |
Bodyweight
range 8-40Kg.
The
Lack is probably the most popular "non reabreathing"
circuit in use today, with a suggested minimum flow rate 1 times
minute volume, economy as well as good oxygenation are achieved.
Supplied with 1.6mtr parallel patient tubing, 2 litre rebreathing
bag, bag adaptor, 30mm gas scavenging valve.
Mapleson
classification:
Modified
"A"
Stock
code 103-060
 |