V3404P Multi-Parameter Patient Monitor
|
|
Displays |
|
Temperature |
|
|
Display |
Electroluminescent |
Range |
0 to 60 °C, 32 to 140 °F |
|
Waveforms |
ECG, Plethysmogram |
Accuracy |
+/-1 °C |
|
SpO2 |
3 digit (LED display) |
Display |
3-digit 10X14 pixel font (EL Panel), update rate = 1Hz,Splits time on screen with respiration, when on. |
|
Pulse rate/ |
3 digit (LED display) |
Alarms |
No alarms for temperature |
|
Pulse Strength |
Logarithmically scaled 10 segment LED bar graph |
Range |
Sensitivity level 100, used for larger animalsSensitivity level 10, used for small animals |
|
Indicators Low Battery |
"LOW BATTERY" message when 30 minutes of battery life remains |
Rate
|
5 to 150 BrPM (breathes per minute) |
|
Audio Disabled |
SILENCED BELL icon indicates temporary or indefinite status |
Accuracy |
> of +/-2% or +/-2 BrPM over full range |
|
Asystole Alarm |
ALARM LED will flash, ASYSTOLE message on screen |
Bandwidth |
0.16 to 2 Hz |
|
SpO2 Sensor |
Message indicates sensor problem |
Minimum Signal |
10mL (Volume of air passing thermistor) |
|
SpO2 Search |
Message indicates monitor is searching for a pulse |
Display |
3-digit 10X14 pixel font (EL Panel)(update rate = 1Hz)Splits time on screen with temperature, when on. |
|
Artifact |
Message indicates presence of excess motion or other artifacts |
Dimensions |
3.5"x
10"x5.5" HWD |
|
ECG/Lead Fail |
Message indicates a lead disconnect condition |
Weight |
5lb (2.27Kg) |
|
Charge |
Green LED indicates external power and battery is charging |
AC charger |
230v, 50/60Hz |
|
Pace Detect |
A line appears on screen when pacemaker signal is present |
Battery Life |
Standard Lead Acid |
|
SpO2 |
|
1.5 hours of continuous use,fully charged in 6 hours |
|
|
Accuracy |
±2 @ 70-100%, ±3 @ 50-69% |
Printer Output |
Serial/Analog |
|
Averaging |
4, 8, 16 Beat Average |
Optional digital (remote alarm) interface |
|
|
Alarms |
Low 50
100% and Off |
Printer (optional) |
Stock code V3408 provides data log trends & waveform printouts |
|
Pulse rate SpO2 or heart rate (ECG) |
Environmental Specifications |
||
|
Range |
20-350 bpm |
Operating Temp. |
0°C-55°C |
|
Averaging |
8 or 16 Second Average |
Storage Temp. |
- 40°C to 75°C |
|
Alarms |
Low 20 - 350 bpm
and Off |
Relative Humidity |
10- 95% (Storage) |
|
ECG |
Safety Standards |
||
|
Configuration |
3 lead standard or |
Safety |
EN60601-1,EN60601-1-1, UL544, CSA Srd.C22.2 No.125-1984 |
|
Lead Selection |
I, II, III, aVR,
aVL, aVF and V |
EMC |
EN60601-1-2 |
|
Pace Detect |
Yes |
Trends |
|
|
Sweep Speed |
12.5, 25 or 50mm/Sec |
Stock Code |
V3404 |
Specification Subject to Change Without Notice