burtons logo The Advisor Vital Signs Patient Monitor

picture of the Advisor Multi Parameter Monitor

Pulse oximeter, Capnograph, ECG Monitor, NIBP Monitor,

Invasive BP Monitor, Temperature Monitor.

The Ultimate Monitor You Can Afford!

Key Features:
4-trace, 10.4 inch Active Matrix Color TFT display.
Intuitive point and click user-interface.
On-screen trending of all monitored parameters.
Compact - with a maximum weight of 12 pounds.
Integrated handle enhances portability.
Optional high-resolution dual trace printer.
SurgiVet Serial Auto correlation (SAC) Technology.

 

 The Advisor is available in four models

Model V9200

Monitored Parameters: ECG, Pulse Oximetry, Non Invasive Blood Pressure

Model V9201

Monitored Parameters: ECG, Pulse Oximetry, Non Invasive Blood Pressure, Capnography

Model V9203

Monitored Parameters: ECG, Pulse Oximetry, Non Invasive Blood Pressure, Capnography, Invasive Blood Pressure (2 channel), Temperature (2 Channel).

Model V9204

 Same as model V9203 but also includes a thermal printer.

Use this link to download a brochure of this product.

return to patient monitoring main page

Need a demo? Use this link

Use this link to request a quotation

Back to the Veterinary Index

Each Advisor model is supplied with the following items

 Model V9200

Your choice of either a 3 or 5 lead ECG patient cable, Lingual SpO2 sensor, "C" Style SpO2 sensor, set of 4 Purple NIBP cuffs.

 Model V9201

Your choice of either a 3 or 5 lead ECG patient cable, Lingual SpO2 sensor, "C" Style SpO2 sensor, set of 4 Purple NIBP cuffs, Pack of CO2 circuit sample lines, Pack of CO2 sample fittings, Pack of nasal CO2sample lines, Spare Moisture Trap.

Model V9203

Your choice of either a 3 or 5 lead ECG patient cable, Lingual SpO2 sensor, "C" Style SpO2 sensor, set of 4 Purple NIBP cuffs, 1x pack of CO2 circuit sample lines, 1 x pack of CO2 sample fittings, 1x pack of nasal CO2sample lines, 1x Spare Moisture Trap, 1x IV transducer set, 1x transducer interface cable, 1x temperature sensor, 1x temperature sensor interface cable.

Model V9204

Your choice of either a 3 or 5 lead ECG patient cable, Lingual SpO2 sensor, "C" Style SpO2 sensor, set of 4 Purple NIBP cuffs, 1x pack of CO2 circuit sample lines, 1 x pack of CO2 sample fittings, 1x pack of nasal CO2sample lines, 1x Spare Moisture Trap, 1x IV transducer set, 1x transducer interface cable, 1x temperature sensor, 1x temperature sensor interface cable.

Specifications:

Displays & Controls:

Main Display: 10.4” High-Resolution Active

Matrix Color LCD

Resolution = 640 x 480 pixels

Function Keys: On/Off, BP Zero All, NIBP start/stop

Print start/stop, Alarm Silence, rotary encoded push-button

control knob

Indicators:

AC Power Green LED w/power plug icon

Battery Power Green LED w/battery icon

SpO2:

Range 0-100% (functional saturation)

Accuracy +2% @ 70-100% +3% @ 50-69%

Alarm Range 50-100% and Off

Averaging 4,8,16 pulse beat average

Pulse Rate (SpO2) or Heart Rate (ECG):

Range 20-350 bpm (SpO2)

20-240 bpm (NIBP)

20-350 bpm (ECG)

Accuracy +2% bpm or +2% (whichever is greater)

Alarm Range 20-350 bpm & Off (1 bpm steps)

Averaging Fixed at 8 seconds

ECG:

Configuration 3 lead standard or 5 lead optional

Lead Selection I, II, III, aVL, aVR, aVF and V

Display Gain X1/2, X1, X2, X4

Defib. Protection Yes

Sweep Speed 12.5 mm/sec, 25mm/sec and 50mm/sec

Non-Invasive Blood Pressure:

Range 20-250 mmHg

Accuracy Meets or exceeds SP10-1992 Standard

for NIBP accuracy

Cuff Pressure Accuracy +3mmHg or +2% (whichever is greater)

Inflation Pressure 50-300 mmHg

Default Inflation Pressure 100 mmHg (Horse)

150 mmHg (Dog)

200 mmHg (Cat)

Alarm Range 20-250mmHg &Off (1 mmHg steps)

 

2 Channel Invasive Pressure:

Range -50mmHg - 300 mmHg (after zeroing)

Accuracy +1mmHg or +1% (whichever is greater)

Alarm Range -50 - 300mmHg (in 1 mmHg steps)

2 Channel Temperature:

Range 0-50°C (32-122°F)

Accuracy +0.1°C (+0.2°F) plus temp. sensor tolerance

Resolution 0.1°C (0.1°F)

Alarm Range 20.0-50.0°C (68-122°F) & Off

Sensor Compatibility YSI 400 or 700 series

Sidestream Capnography :

Measurement Non-dispersive IR absorption

Measurement Range 0-10% CO2 STPD

Display Range 0-100 mmHg; 0-13.3 kPa; 0-10%CO2

Accuracy +2mmHg or 4% of reading

(whichever is greater) (10%CO2)

Alarm Range 0-100 mmHg; 0-13.3 kPa; 0-10%

CO2 & Off

N2O Compensation Selectable 40% (default = Off

Averaging 4 breath

Flowrate 140 ml/min+20ml

Printer - Optional:

Dual trace printer provides waveforms, annotation

snapshot,

continuous, print on alarms and trend tables.

Dimensions: 12” H x 13-1/4” W x 7” D

30.5 cm H x 34.0 cm W x 18.0 cm D

Weight:

without battery or capnograph 5.4kg

with battery or capnograph 6.8kg

Power Requirements:

AC Input 90-120 VAC, 230-240 VAC,

50/60 Hz, 0.6 A

Battery (optional) 1 hour operation, 4 hour recharge

Auxiliary Inputs/Outputs: Serial RS232 Standard

Environmental Specifications:

Operating Temperature 0-40°C (32-104°F)

Storage Temperature -40-75°C (-40 -167°F)

Relative Humidity 15-95% (operating)

(non-condensing) 10-95% (storage)

 